Recommended
ABC3090-A Modbus RTU Master - PROFINET Device / EthernetIP Adapter / Modbus TCP Server / EtherCAT Slave
The Anybus Communicator EtherNet/IP Scanner to Modbus RTU enables you to connect EtherNet/IP devices to Modbus RTU control systems.
High price? Log in and buy cheaper
Free shipping from €300
Promocja cenowa na model HDR-15-5
Product intended for professional use onlyModel | Availability | Warranty | Wishlist | Your Price | Your Price | Items Quantity Add |
---|---|---|---|---|---|---|
ABC3310-A Ethernet/IP Scanner – Modbus RTU Server | Out of stock | Warranty: | €1,336.00 €1,643.28 | Login to check your price |
Anybus Communicators ensure reliable, secure, and high-speed data transfer between different industrial networks. Thanks to our intuitive web-based user interface, they're also incredibly easy to use.
Powered by the award-winning NP40 network processor, it enables instant transfer of up to 1500 bytes (network dependent) between networks, totaling 3000 bytes.
Instant data transfer lets you take advantage of high-speed industrial networks.
The Communicator provides hardware-accelerated endian conversion (byte swap), saving processing time on the PLC.
Use the intuitive web-based user interface to easily configure the Communicator via the drag-and-drop functionality or to analyze live data and generate support packages.
Directly import EDS files in web user interface, eliminating the need to install third-party software.
Despite advanced security, human error often causes breaches. Our Communicator’s physical security switch can lock configurations and block web interface access, enhancing security.
The Communicator has forward-facing ports and is designed for IP20 and DIN-rail mounting, enabling you to install it with ease, close to connected devices, thereby reducing wiring requirements.
The user interface displays real-time connection status and I/O data mapping for easy troubleshooting. Easily generate a support file containing all the necessary information.
Thanks to carefully selected industrial components the Communicator operates reliably in harsh environments, ensuring uptime and longevity. Our confidence in quality is reflected in a 5-year warranty.
HMS maintains every part of the Communicator, including network updates, throughout the product’s lifecycle.
Parameter | Value |
---|---|
Brand | Anybus |
Country of Origin | Sweden |
Dual Usage | No |
Export Control Classification Number (ECCN) | 5A991.b.1 |
Model Code | 40-ETH-ETH-B |
Item Number | ABC3328-A |
Predecessor | AB7699-F |
HS Code | 8517620000 |
Parameter | Value |
---|---|
CE | Yes |
UL | Yes |
UL Information | E214107: Ord.Loc UL 61010-1, CSA C22.2 No. 61010-1, UL 61010-2-201, CSA C22.2 No. 61010-2-201 |
KC | Yes |
EMC | Yes |
FCC | No |
Environment | EN 55016-2-3 Class A, EN 55032 Class A, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6 |
Waste Certification (WEEE) | Yes |
Protection Class IP | IP20 |
Recycle / Disposal | Yes |
RoHS Compliant | Yes |
Parameter | Value |
---|---|
Contains Battery | No |
Connectors / Input / Output | 2xRJ45; RJ45 Config port |
DIP & Rotary Switches | Security lock switch |
Push Buttons | Factory reset |
Parameter | Value |
---|---|
Net Width (mm) | 27 mm |
Net Height (mm) | 144 mm |
Net Depth (mm) | 98 mm |
Net Weight (g) | 150 g |
Mounting | DIN-rail (EN 50022 standard) |
Current Consumption Type Value at Vcc Nom (mA) | 90mA @ 24V DC (2.2W) |
Current Consumption Max value at Vcc nom (mA) | 125mA @ 24V DC (3W) |
Input Voltage (V) | 12-30V DC |
Power Connector | 3-pin, 5.08 Phoenix plug connector |
Reverse Polarity Protection | Yes |
Short Circuit Protection | Yes |
Isolation | Yes |
Operating Temperature (°C) | -25 to 70 |
Storage Temperature (°C) | -40 to 85 |
Housing Materials | PC ABS, UL 94 VO |
Packaging Material | Cardboard |
Packed Dimensions (mm) | 115 x 170 x 35 |
Packed Weight (g) | 185 g |
Parameter | Value |
---|---|
EtherNet/IP Mode | Scanner / Master |
Supported Functionality | EDS import; Endian conversion (byte swap); LiveList; DataExchangeControl; QoS; CT20 ODVA Conformance |
EtherNet/IP Bandwidth | 10/100MBit down to 1ms cycle time |
Input Data Size | 1500 bytes |
Output Data Size | 1500 bytes |
Number of Adapters | 32 |
Configuration File | EDS available |
Mode | Slave mode |
Supported Functionality | RS-232; RS-485; Endian conversion; 8 data bit; None, Odd, Even Parity; 1 or 2 stop bit; ABX compatible mode |
Baud Rate | 1200, 1800, 2400, 4800, 7200, 9600, 14400, 19200, 35700, 38400, 57600, 115200, 128000 bit/s |
Input Data Size | 1500 bytes |
Output Data Size | 1500 bytes |
Functions Supported | 1, 2, 3, 4, 5, 6, 8, 15, 16, 22, 23, 43/14 |
Recommended
ABC3090-A Modbus RTU Master - PROFINET Device / EthernetIP Adapter / Modbus TCP Server / EtherCAT Slave
Recommended
ABC4011 - EtherNet/IP adapter - Modbus TCP server
Recommended
ABC3090EX-A Modbus RTU Master - PROFINET Device / EthernetIP Adapter / Modbus TCP Server / EtherCAT Slave ATEX
Recommended
ABC4013 PROFINET IO-Device - EtherNet/IP slave
Have questions? Need advice? Call or write to us!