Recommended
5-port entry-level unmanaged Ethernet switches with metal housing
High price? Log in and buy cheaper
Place the order by 12:00, the package will be shipped on the same day
Free shipping from €300
Promocja cenowa na model HDR-15-5
Model | Availability | Warranty | Wishlist | Your Price | Your Price | Items Quantity Add |
---|---|---|---|---|---|---|
MGate 5217I-600-T Modbus RTU/ASCII/TCP-to-BACnet/IP, 600 points Recommended | In stock | Warranty: | €622.00 €765.06 | Login to check your price |
Recommended
Model | Availability | Warranty | Wishlist | Your Price | Your Price | Items Quantity Add |
---|---|---|---|---|---|---|
MGate 5217I-1200-T Modbus RTU/ASCII/TCP-to-BACnet/IP, 1200 points | Out of stock | Warranty: | €1,127.00 €1,386.21 | Login to check your price |
The MGate 5217I Series comprise 2-port BACnet gateways that can convert Modbus RTU/ACSII/TCP to BACnet/IP protocol. Depending on the size and the scale of the network, the gateways provide 600-point and 1200-point models. All models are rugged, DIN-rail mountable, operate in wide temperatures, and offer built-in 2kV isolation for serial signals.
The MGate 5217I Series comes with an intuitive UI design to make configuration easy. With that, you can easily access protocol conversion modes and finish the configuration in a few steps instead of installing an additional engineering utility in your computer. Besides, the MGate can generate Modbus commands by importing an Excel spreadsheet, which makes it easy to edit Modbus commands.
The MGate 5217I gateways support Modbus and BACnet/IP Protocol Traffic Monitor and Diagnostics for easy troubleshooting, especially during the installation stage. Communication issues could be caused by incorrect software parameters, such as the wrong slave ID and register address, or an incorrect command configuration. With Diagnostics, you can check the communication status and view values at a glance. With Modbus/BACnet Protocol Traffic Monitor, you can check the captured data and easily identify the root cause.
Using network devices that are IEC 62443-4-2 compliant and equipped with basic security capabilities is an effective precautionary measure to ward off cyberattacks. The MGate 5217I Series is capable of several basic security capabilities, including password cracking defense, sniffer and data breach prevention, whitelisting, and the account management.
10/100BaseT(X) Ports (RJ45 connector) | 2 Auto MDI/MDI-X connection |
Magnetic Isolation Protection | 1.5 kV (built-in) |
Industrial Protocols | Modbus TCP Client (Master), BACnet/IP Server (Slave) |
Configuration Options | Web Console (HTTP/HTTPS), Device Search Utility (DSU), Telnet Console |
Management | ARP, DHCP Client, DNS, HTTP, HTTPS, SMTP, SNMP Trap, SNMPv1/v2c/v3, TCP/IP, Telnet, UDP, NTP Client |
MIB | RFC1213, RFC1317 |
Time Management | NTP Client |
No. of Ports | 2 |
Connector | DB9 male |
Serial Standards | RS-232/422/485 |
Baudrate | 50 bps to 921.6 kbps |
Data Bits | 7, 8 |
Parity | None, Even, Odd, Space, Mark |
Stop Bits | 1, 2 |
Flow Control | RTS Toggle (RS-232 only), RTS/CTS, DTR/DSR |
RS-485 Data Direction Control | ADDC® (automatic data direction control) |
Pull High/Low Resistor for RS-485 | 1 kilo-ohm, 150 kilo-ohms |
Terminator for RS-485 | 120 ohms |
Isolation | 2 kV (built-in) |
RS-232 | TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND |
RS-422 | Tx+, Tx-, Rx+, Rx-, GND |
RS-485-2w | Data+, Data-, GND |
RS-485-4w | Tx+, Tx-, Rx+, Rx-, GND |
Industrial Protocols | Modbus RTU/ASCII Master |
Mode | Master |
Functions Supported | 1, 2, 3, 4, 5, 6, 16 |
Max. No. of Commands | MGate 5217I-600-T: 600 MGate 5217I-1200-T: 1200 |
Mode | Client (Master) |
Functions Supported | 1, 2, 3, 4, 5, 6, 16 |
Max. No. of Server Connections | 32 |
Max. No. of Commands | MGate 5217I-600-T: 600 MGate 5217I-1200-T: 1200 |
Mode | Server (Slave) |
Memory Size | MGate 5217I-600-T: 600 points MGate 5217I-1200-T: 1200 points |
Supported BACnet Object | Binary Input Binary Output Binary Value Analog Input Analog Output Analog Value Multi-state Input Multi-state Output Multi-state Value Integer Value Positive Integer Value |
Input Voltage | 24 VAC, 12 to 48 VDC |
Input Current | 300 mA @ 24 VAC 510 mA @ 12 VDC |
Power Connector | Screw-fastened Euroblock terminal |
Contact Current Rating | Resistive load: 1 A @ 30 VDC |
Housing | Plastic |
IP Rating | IP30 |
Dimensions (without ears) | 29 x 89.2 x 118.5 mm (1.14 x 3.51 x 4.67 in) |
Dimensions (with ears) | 29 x 89.2 x 124.5 mm (1.14 x 3.51 x 4.90 in) |
Weight | 380 g (0.84 lb) |
Operating Temperature | -40 to 75°C (-40 to 167°F) |
Storage Temperature (package included) | -40 to 85°C (-40 to 185°F) |
Ambient Relative Humidity | 5 to 95% (non-condensing) |
EMC | EN 55032/35 |
EMI | CISPR 32, FCC Part 15B Class A |
EMS | IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m IEC 61000-4-4 EFT: Power: 4 kV; Signal: 2 kV IEC 61000-4-5 Surge: Power: 2 kV IEC 61000-4-6 CS: 10 V IEC 61000-4-8 PFMF IEC 61000-4-11 |
Safety | UL 62368-1, IEC 62368-1 |
Freefall | IEC 60068-2-32 |
Shock | IEC 60068-2-27 |
Vibration | IEC 60068-2-6, IEC 60068-2-64 |
International Approval | KC |
Time | 1,277,500 hrs |
Standards | Telcordia SR332 |
Warranty Period | 5 years |
Details | See www.moxa.com/warranty |
Recommended
5-port entry-level unmanaged Ethernet switches with metal housing
Recommended
8-port entry-level unmanaged Ethernet switches with metal housing
Recommended
8+2G-port Gigabit unmanaged Ethernet switches
Recommended
5-port entry-level unmanaged Ethernet switches