MGate 5118

1-port CAN-J1939 to Modbus/PROFINET/EtherNet/IP gateways

  • Converts J1939 to Modbus, PROFINET, or EtherNet/IP
  • Supports Modbus RTU/ASCII/TCP master/client and slave/server
  • Supports EtherNet/IP Adapter
  • Supports PROFINET IO device
  • Supports J1939 protocol
  • Effortless configuration via web-based wizard
  • Built-in Ethernet cascading for easy wiring
  • Embedded traffic monitoring/diagnostic information for easy troubleshooting
  • microSD card for configuration backup/duplication and event logs
  • Status monitoring and fault protection for easy maintenance
  • CAN bus and serial port with 2 kV isolation protection
  • -40 to 75°C wide operating temperature models available
  • Security features based on IEC 62443
Price from €607.00 Net price

High price? Log in and buy cheaper

In stock

Place the order by 12:00, the package will be shipped on the same day

Free shipping from €300

See 2 models

Promocja cenowa na model HDR-15-5

Product intended for professional use only
Nowa brama komunikacyjna firmy Moxa konwertuje J1939 na Modbus/PROFINET/EtherNet

MGate 5118

Models

  • ModelAvailabilityWarrantyWishlist
    Your Price
    Your Price
    MGate 5118
    1-port J1939 to Modbus/PROFINET/EtherNet/IP gateway
    In stock
    Warranty:
    €607.00
    €746.61
    Login to check your price
    MGate 5118
    1-port J1939 to Modbus/PROFINET/EtherNet/IP gateway
    Availability:
    In stock
    Net price:
    €607.00
  • ModelAvailabilityWarrantyWishlist
    Your Price
    Your Price
    MGate 5118-T
    1-port J1939 to Modbus/PROFINET/EtherNet/IP gateway
    Out of stock Warranty:
    €764.00
    €939.72
    Login to check your price
    MGate 5118-T
    1-port J1939 to Modbus/PROFINET/EtherNet/IP gateway
    Availability: Out of stock
    Net price:
    €764.00

Accessories

Description

The MGate 5118 industrial protocol gateways support the SAE J1939 protocol, which is based on CAN bus (Controller Area Network). SAE J1939 is used to implement communication and diagnostics among vehicle components, diesel engine generators, and compression engines, and is suitable for the heavy-duty truck industry and backup power systems. It is now common to use an engine control unit (ECU) to control these kinds of devices, and more and more applications are using PLCs for process automation to monitor the status of J1939 devices connected behind the ECU.

The MGate 5118 gateways support the conversion of J1939 data to Modbus RTU/ASCII/TCP, EtherNet/IP, or PROFINET protocols to support most PLC applications. Devices that support the J1939 protocol can be monitored and controlled by PLCs and SCADA systems that use the Modbus RTU/ASCII/TCP, EtherNet/IP, and PROFINET protocols. With the MGate 5118, you can use the same gateway in a variety of PLC environments.

Key-in-Free J1939 Command

The J1939 protocol is designed to retrieve a wide range of data from CAN-J1939 devices. To eliminate the need to key in all J1939 commands into the gateway by hand, MGate 5118 gateways can auto detect the output commands used by the CAN device.

With a single click in the web console, all of the output commands from your CAN device will be detected by the gateway automatically. The commands will be displayed in the web console’s command list, and then can be further modified by the user if needed. The MGate 5118 gateways make it much easier for users to connect PLCs with CAN devices.

A Variety of Maintenance Functions

The MGate 5118 gateways support a web console for easy configuration and maintenance, and the built-in traffic monitor function monitors J1939 protocol traffic, allowing users to monitor the status of connected CAN devices, including error count, packet count, and bus-offline. The traffic monitor function can also be used to troubleshoot CAN devices. The diagnostics tool helps users to check CAN device settings and indicates CAN device availability by reading the J1939 network address. In addition, the MGate 5118 gateways have a built-in Live List function for when two or more J1939 devices are connected to the same CAN bus. This function shows the PGN and address of packets transmitted from each device, giving users the ability to gage the loading of the CAN bus.

To detect loose cables, the MGate 5118 gateways support status monitoring and fault protection functions. The status monitoring function notifies a PLC when the cable between the gateway and CAN device is loose. In addition, the fault protection function executes actions predefined by the user when the cable between the gateway and PLC is loose.

Technical Specification

  • Ethernet Interface
10/100BaseT(X) Ports (RJ45 connector) 2
Auto MDI/MDI-X connection
Magnetic Isolation Protection 1.5 kV (built-in)
  • Ethernet Software Features
Industrial Protocols Modbus TCP Client (Master), Modbus TCP Server (Slave), PROFINET IO Device, EtherNet/IP Scanner, EtherNet/IP Adapter
Configuration Options Web Console (HTTP/HTTPS), Device Search Utility (DSU), Telnet Console
Management ARP, DHCP Client, DNS, HTTP, HTTPS, SMTP, SNMP Trap, SNMPv1/v2c/v3, TCP/IP, Telnet, SSH, UDP, NTP Client
MIB RFC1213, RFC1317
Time Management NTP Client
  • Serial Interface
Console Port RS-232 (TxD, RxD, GND), 8-pin RJ45 (115200, n, 8, 1)
No. of Ports 1
Connector DB9 male
Serial Standards RS-232/422/485
Baudrate 50 bps to 921.6 kbps
Data Bits 7, 8
Parity None, Even, Odd, Space, Mark
Stop Bits 1, 2
Flow Control RTS Toggle (RS-232 only), RTS/CTS
Pull High/Low Resistor for RS-485 1 kilo-ohm, 150 kilo-ohms
Terminator for RS-485 120 ohms
Isolation 2 kV
  • Serial Signals
RS-232 TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
RS-422 Tx+, Tx-, Rx+, Rx-, GND
RS-485-2w Data+, Data-, GND
RS-485-4w Tx+, Tx-, Rx+, Rx-, GND
  • Serial Software Features
Configuration Options Serial Console
Industrial Protocols J1939, Modbus RTU/ASCII Master, Modbus RTU/ASCII Slave
  • Modbus RTU/ASCII
Mode Master, Slave
Functions Supported 1, 2, 3, 4, 5, 6, 15, 16, 23
Max. No. of Commands 128
  • Modbus TCP
Mode Client (Master), Server (Slave)
Functions Supported 1, 2, 3, 4, 5, 6, 15, 16, 23
Max. No. of Client Connections 16
Max. No. of Server Connections 32
Max. No. of Commands 128
  • PROFINET
Mode IO Device
Max. No. of IO Controller Connections 1 (for read/write)
Input Data Size 512 bytes
Output Data Size 512 bytes
  • EtherNet/IP
Mode Scanner, Adapter
CIP Objects Supported Identity, Message Router, Assembly, Connection Manager, TCP/IP interface, Ethernet link, Port
Max. No. of Scanner Connections 1 (for read-only), 1 (for read/write)
Max. No. of Adapter Connections 4
Input Data Size 496 bytes
Output Data Size 496 bytes
  • CAN Interface
Industrial Protocols J1939
No. of Ports 1
Connector Spring-type Euroblock terminal
Baudrate 250 kbps, 500 kbps
Terminator 120 ohms
Isolation 2 kV (built-in)
  • J1939
Max. No. of Commands 256
Input Data Size 2048 bytes
Output Data Size 2048 bytes
  • Memory
microSD Slot Up to 32 GB (SD 2.0 compatible)
  • Power Parameters
Input Voltage 12 to 48 VDC
Input Current 416 mA @ 12 VDC
Power Connector Spring-type Euroblock terminal
  • Relays
Contact Current Rating Resistive load: 2 A @ 30 VDC
  • Physical Characteristics
Housing Metal
IP Rating IP30
Dimensions 45.8 x 105 x 134 mm (1.8 x 4.13 x 5.28 in)
Weight 589 g (1.30 lb)
  • Environmental Limits
Operating Temperature MGate 5118: 0 to 60°C (32 to 140°F)
MGate 5118-T: -40 to 75°C (-40 to 167°F)
Storage Temperature (package included) -40 to 85°C (-40 to 185°F)
Ambient Relative Humidity 5 to 95% (non-condensing)
  • Standards and Certifications
Safety EN 60950-1, UL 61010-2-201
EMC EN 61000-6-2/-6-4
EMI CISPR 32, FCC Part 15B Class A
EMS IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m
IEC 61000-4-4 EFT: Power: 4 kV; Signal: 4 kV
IEC 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV
IEC 61000-4-6 CS: 150 kHz to 80 MHz: 10 V/m; Signal: 10 V/m
IEC 61000-4-8 PFMF
Hazardous Locations ATEX, Class I Division 2, IECEx
Freefall IEC 60068-2-32
Shock IEC 60068-2-27
Vibration IEC 60068-2-6, IEC 60068-2-64
  • MTBF
Time 727,873 hrs
Standards Telcordia SR332

Recommended Products

Contact an Elmark specialist